Product features • Small size for high current applications • 63 Vdc/100 Vdc/125 Vdc Voltage rating • Ceramic body with bolt in terminal design • UL recognized
Applications • Mild hybrid automotive • Vehicle power distribution • Material handling systems • All supercapacitor and battery systems • High current wire protection
Agency information • cURus recognized file:
E91958, guide JFHR2 and JFHR8
Environmental compliance
Typical cold resistance
Part number
Rated current (A)
Voltage rating (Vdc)
Breaking capacity1
(mOhms)2
AMX(L)-80
80
63/100/125
8 kA @ 63 Vdc* 6 KA @ 100 Vdc* 3 kA @ 125 Vdc
0.51
AMX(L)-100
100
63/100/125
8 kA @ 63 Vdc* 6 KA @ 100 Vdc* 3 kA @ 125 Vdc
0.43
AMX(L)-150
150
63/100/125
8 kA @ 63 Vdc* 6 KA @ 100 Vdc* 3 kA @ 125 Vdc
0.33
AMX(L)-200
200
63/100/125
8 kA @ 63 Vdc* 6 KA @ 100 Vdc* 3 kA @ 125 Vdc
0.24
AMX(L)-250
250
63/100/125
8 kA @ 63 Vdc* 6 KA @ 100 Vdc* 3 kA @ 125 Vdc
0.19
AMX(L)-300
300
63/100/125
8 kA @ 63 Vdc* 6 KA @ 100 Vdc* 3 kA @ 125 Vdc
0.16
AMX(L)-350
350
63/100/125
3 kA @ 125 Vdc
0.13