➢ Fast Acting High current brick fuse ➢ Surface mount deign to save space ➢ Ceramic Suqare body with end cap design➢ Designed to UL248-1/14
Electrical Characteristics
Specifications
1. AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing) 2. DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds,
battery source) 3. Typical Pre-arcing I2t are measured at 10In Current, DC battery bank, but not exceeding the interrupting
rating, time constant of calibrated circuit less than 50 microseconds) 4. Internal qualification for 20A-30A @ 100Vdc, UL Approval is pending
Dimension
Recommended Pad Layout
Recommend trace thickness is 3oz; the minimum trace width is 10mm;
Recommend stencil thickness is 0.15mm;
Infrared Reflow
• Temperature: 260° C • Time: 30 Seconds Maximum
Temperature derating curve
⚫ Normal Operating Temperature: 25°C±2°C ⚫ Operating Temperature: -55°C to 125°C with proper correction factor applied.
⚫ Chart of correction factor
Package and Minimum order QTY
20A-30A: 1500pcs fuses in tape (width 24mm) and reel (dia. 13inch);