➢ Rapid interruption of excessive current ➢ Compatible with reflow ➢ Ceramic body and silver-plated copper terminal➢ Excellent environmental integrity ➢ One time positive disconnect ➢ RoHS compliant
➢ Designed to UL 248-14
1.AC Interrupting Rating measured at designated voltage, 100% power factor; DC Interrupting Rating
measured at designated voltage, time constant of less than 50 microseconds, battery source
2.DC Cold Resistance are measured at <10% of rated current in the ambient temperature of 25°C
3.Typical Pre-arcing I2t are measured at 10In Current
Dimension
Drawing not to scale (Unit: mm)
Soldering method
➢ Recommended land pattern (mm)
Recommend Stencil thickness is 0.15mm
Infrared Reflow
• Temperature: 260° C • Time: 30 Seconds Maximum
Temperature Derating Curve
E355868
Package
Normal Operating Temperature: 25°C± 2°C Operating Temperature: -55°C to 125°C with proper correction factor applied.
Chart of correction factor
Storage Temperature: -55°C to 125°C
Package
1000 fuses on 12mm tape-and-reel per EIA Standard 481.