产品中心



							
re-production and sample electric vehicle power fuses — 500 Vdc, 50-400 A
   Fuse size/ratings 
 Description 
 Specifications: 
 
 Fuse ratings 
 * For system parameters below 500 Vdc and 20 kA, see clearing I2t correction factors on page 9. **50 percent of fuse label amp rating tested at 23°C ± 2°C. Dimensions† — mm 
  | 
  | 
20 mm diameter DC minimum melt / maximum clearing time-current curves — multiple of rated current
For 50 to 100 amp fuses supplied via DC rectifier @ 500 Vdc and time constant (L/R) 2 ms ± 0.5 ms

For 125 to 150 amp fuses supplied via DC rectifier @ 500 Vdc and time constant (L/R) 2 ms ± 0.5 ms

25 mm diameter DC minimum melt / maximum clearing time-current curves — multiple of rated current
For 100 to 150 amp fuses supplied via DC rectifier @ 500 Vdc and time constant (L/R) 2 ms ± 0.5 ms

25 mm diameter DC minimum melt / maximum clearing time-current curves — multiple of rated current
For 175 to 250 amp fuses supplied via DC rectifier @ 500 Vdc and time constant (L/R) 2 ms ± 0.5 ms

30 mm diameter DC minimum melt / maximum clearing time-current curves — multiple of rated current
For 200 to 400 amp fuses supplied via DC rectifier @ 500 Vdc and time constant (L/R) 2 ms ± 0.5 ms

Power loss correction factors

Melting time correction factors (tolerance band)*

Clearing I2t correction factors — 5 to 10 kA and 20 kA

* Correction factor applies to I2t clearing at 20 kA in the catalog number table on page 2.