Catalog symbol: CHCC_ (Class CC) CHM_ (UL® midget/IEC® 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic) Description: Eaton’s Bussmann® series CH DIN-Rail fuse holders are for UL Class CC and midget fuses, and IEC 10x38 fuses. They are available with and without indication in 1-, 2- and 3-pole versions. A variety of accessories extends their application flexibility and they may be ganged together to meet specific application requirements. For other Bussmann series CH fuse holders, please see the following data sheets. Features and benefits:
| Specifications: Ratings Volts 600V (or less) UL690V (or less) IEC 1000Vdc (or less) photovoltaic (PV) Amps 32A IEC Short-Circuit Current Rating (SCCR) 200kA RMS Sym. (CHCC, CHM*) * CHM SCCR is fuse interrupting rating dependent. Agency information • UL Listed File E14853, Guide IZLT, Recognized IZLT2 • UL Listed to E348242 and Guide IZMR (CHPV)• CSA® File 47235, CHPV and CHM - Class 6225-30, CHCC - Class 6225-01• IEC 60269-2 (CHM, CHPV) Mounting • 35mm DIN-Rail
Wire range 75°C and 90°C Cu Solid Stranded Fine stranded Terminals Single or dual conductors Comb busbar Torque 30 Lb-In (3.4 N•m) maximum Flammability UL 94V0, self-extinguishing Storage and operating temperature -4°F (-20°C) to 194°F (90°C) indicating -4°F (-20°C) to 248°F (120°C) non-indicating |
| UL midget and IEC 10x38 CHM holder catalog numbers * All models require 90V minimum for illumination, except CHM1DI-48U that requires 15V minimum. ** SCCR is limited to the interrupting rating of the installed fuse or 200kA, which ever is less. UL Class CC CHCC holder catalog numbers * All models require 90V minimum for illumination, except CHCC1DI-48U that requires 15V minimum. UL and IEC photovoltaic CHPV holder catalog numbers * All models require 90V minimum for illumination. |
Accessories: Bussmann series CH modular fuse holders can be applied using a variety of accessories that facilitate or simplify installation. 35mm DIN-Rails Constructed of high strength stainless steel
Comb busbars Easily distribute power in single-or three-phase systems
Specifications: Agency information • UL 508, File E195399 Pitch • 17.8mm Ratings Volts
• 10kA (default) |
Comb busbar dimensions - mm: Single-phase | Single- and three-phase A dimensions All 15-pole or fewer comb busbars come with endcaps installed. If a comb busbar will be cut-to-length, order additional endcaps to maintain electrical protection. End caps are sold in carton quantities of 50. Order ECAP1P for single-phase and ECAPMP for three phase. |
Comb busbar catalog numbers: |
Power feed terminals: PWR1PLP Single-phase, low profile power feed terminal Ratings Volts 1000Vac/dc Amps 115A Wire range 1/0-10AWG Cu, max torque 50 lb-in (5.6 N•m) Wire temp. rating 60°C* PWR35MM 35mm2 three-phase power feed terminal for three-phase busbars Ratings Volts 1000Vac/dc Amps 115A Wire range 1/0-10AWG Cu, max torque 50 lb-in (5.6 N•m). Wire temp. rating 60°C* PWR50MM 50mm2 direct feed power terminal Ratings Volts 1000Vac/dc Amps 115A . Wire range 1-14AWG Cu, max torque 35 lb-in (3.9 N•m) Wire temp. rating 75°C* | |
Comb busbar safety covers and end caps: FSCVR Spare comb busbar pin safety protection covers (used to cover exposed pins on comb busbars). Sold in quantity of ten strips of five covers each. (FSCVR comes with five covers on a strip. Minimum order is 10 strips or 50 safety covers total.) ECAP1P End cap for single-phase comb busbars. Sold in quantity of fifty. ECAPMP End cap for three-phase comb busbars. Sold in quantity of fifty. | ![]() |
PLC remote fuse monitor The Bussmann series resettable remote fuse monitor permits easy integration with a Programmable Logic Controller (PLC) or other monitoring and control equipment. Signals up to three-phases. Specifications: Power input: 24Vdc / 5mA
Rated impulse voltage • 8kV Local indication Two distinct LEDs indicate unit power (green) and open fuse (red) Upon fuse replacement, the actuation of the reset switch will reset the open fuse LE Flammability rating • UL 94V0 Wiring For power, signal and ground connections use shielded twisted pair 22-24AWG (0.34-0.25mm2) 300V rated wire. Emissions and immunity testing Electrostatic discharge IEC 61000-4-2 Electrical fast transient/burst IEC 6100-4-4 Surge immunity IEC 61000-4-5 Minimum circuit voltage Minimum circuit voltage required across the CH holder is 100Vac for the remote indication device to operate | Installation • Mounts on the left side of the fuse holder and mechanically interlocks with the fuse holder switch handle with hardware provided Degree of protection • Finger-safe IP20 • -4°F (-20°C) to 167°F (75°C) Agency information UL 508
Modular CH DIN-Rail holders for Class CC, midget and PV fuses To order • Specify catalog number CH-PLC PLC wiring schematic PLC power supply |